 Features
* * * * *
Adjustable and Retriggerable Tracking Time Window Monitoring for Sensor Input Enable Input for Triggering Internal Noise Suppression (40 ms) and Retrigger Blocking (640 ms) Two- or Three-wire Applications
Applications
* Motion Detectors * Touch Sensors * Timers
Timer Control for Triac and Relay U2100B
1. Description
The timer control circuit U2100B uses bipolar technology. It has different mode selections (zero voltage switch, phase control and relay control). The output stage is triggered according to input conditions. It can be used in triac application for two- or three-wire systems as a power switch.
Rev. 4769C-INDCO-07/05
Figure 1-1.
Block Diagram with External Circuit
8 C2 0.5 VRef + Trigger signal 6
-VRef
Supply voltage limitation Voltage control monitoring Sync Mode selection
2 -VS 4
C1 L R1 Rsync Load Z D1
Trigger window + -
Noise suppression 40 ms Retrigger delay 640 ms
Control logic
3 Output
RG
Vmains
5
0.65 VRef 1 GND N
Enable 0.6 VRef Ct 0.5 VRef 7 RC Oscillator Rt Divider 1:210 ON OFF
2
U2100B
4769C-INDCO-07/05
U2100B
2. Pin Configuration
Figure 2-1. Pinning DIP8/SO8
GND -VS OUTPUT SYNC 1 2 8 7 VREF OSC TRIG EN
U2100B
3 4 6 5
Table 2-1.
Pin 1 2 3 4 5 6 7 8
Pin Description
Symbol GND -VS OUTPUT SYNC EN TRIG OSC VREF Function Reference point Supply voltage Driver output Synchronization and mode selection Enable Input trigger signal RC oscillator Reference voltage
3
4769C-INDCO-07/05
3. General Description
The monostable integrated power-control circuit U2100B can be used according to the mode selection in relay or triac applications. In addition, it can be used in triac applications for two-wire systems as power switch (the load in series to the switch), where the supply voltage for the control unit is gained from the remaining phase angle (min operation). Figure 3-1. Two-wire Circuit
L
Control
N
Figure 3-2.
Three-wire Circuit
L
Control
N
For three-wire switch systems, two operational modes are possible: - Zero voltage switch operation for triac control - Static operation for relay control
4
U2100B
4769C-INDCO-07/05
U2100B
3.1 Mode Selection Pin 4 and Supply Voltage Pin 2
The operational modes can be selected by the external voltage at the synchronous input pin 4 (clamping). The mode selection determines the current requirement of the relay's or triac's driver stage and hence the selection of the supply voltage.
3.2
Zero Voltage Switch Operation (Figure 3-3 on page 6)
Selection condition: V4 = internal synchronous limitation, without external clamping
VM - VS R 1 0.85 -------------------2 I tot
Itot = IS + Ip + IX where: IS IP IX VM = Supply current of the IC without load = Average trigger current IG = External circuit current requirement = Mains voltage
Required firing pulse width tp
IL x VM 2 t p = -- arcsin ------------------- P x 2
where: IL P = Triac latching current = Power at load Z
V M [V] x 2sin ( x t p [s] ) - 0.7 R sync [k] -------------------------------------------------------------------------------- - 176 -2 1.8 x 10
5
4769C-INDCO-07/05
Figure 3-3.
Zero Voltage Switch Operation
D1
2 -VS
R1 L
C1 4 Sync Rsync
Z
VM
3 Output 1 GND
RG IG N
3.3
DC Operation
Selection condition (Figure 3-4): +V4 = 6.1V, -V4 = internal limitation where: R0 1/10 Xc
VM - VS X c = 0.85 -------------------I tot
Itot = IS + IRel + IX
1 C 0 = ---------------- x XC
Figure 3-4.
DC Operation
2 -VS 1 GND C1
22 V N VM Rel C0 R0 IRel Rsync 230 V~ L
3 Output
4 Sync
6
U2100B
4769C-INDCO-07/05
U2100B
3.4 min Operation
Selection condition (Figure 3-5): -V4 = 6.5 to 7.8V, +V4 = internal limitation
3.6 V R max = R sync ---------------------------------------V R(peak) - 3.6 V 10 V R min = R sync ---------------------------------------V M x 2 - 10 V
VR(peak) is the peak voltage of the remaining phase angle, which should be high enough to generate the supply voltage, VS. Figure 3-5. min Operation (Two-wire Operation)
D1 IN 4007 -VS 2 C1 4 Sync Rsync R 1N4148 6.8 V 3 Output 1 GND RG IG N VR(peak) C0 R0 Z L 22 V
VM 230 V~
C1 Co Ro Rsync R RG D1
= = = = = = =
100 F/35V 0.33 F/250V ~ 390 220 k 10 k 390 IN 4007
7
4769C-INDCO-07/05
3.5
Tracking Time Pin 7
An internal RC oscillator with a following divider stage 1:210 allows a very long and reproducible tracking time. The RC values for the required final time, tt, can be calculated as follows:
t t [s] x 10 R t [] = ---------------------------------------------------1.6 x 1024 x C t [F] t t [s] x 10 C t [F ] = -------------------------------------------------1.6 x 1024 x R t [] C t [F] x R t [] x 1.6 x 1024 t t [s] = -------------------------------------------------------------------------6 10
6 6
3.6
Trigger Inputs Pins 5 and 6
Two AND-connected, identical inputs determine the trigger conditions of the monostable time stages (Figure 3-6, Figure 3-7 on page 9), i.e., both inputs must be in position "ON" so that the output is switched on. The tracking time starts after the trigger conditions have elapsed. The output ON state is given until the tracking time has elapsed. Input pin 5 is a simple comparator, whereas input pin 6 is designed as a window discriminator. The noise suppression for tON = 40 ms prevents peak noise signals at the inputs which could trigger the circuit. At the same time, the retrigger function is delayed for a duration of 640 ms (tOFF) to avoid noise signal that may trigger the relay. Figure 3-6. Trigger Condition, Pin 5
V5 0 OFF T1 = 0.5 VRef Hysteresis T2 = 0.65 VRef ON VRef
8
U2100B
4769C-INDCO-07/05
U2100B
Figure 3-7. Trigger Condition, Pin 6
V6 0 ON T1 = 0.5 VRef T2 = 0.65 VRef OFF ON VRef
4. Absolute Maximum Ratings
Stresses beyond those listed under "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in the operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Parameters Supply Supply current Peak current t 10 ms Supply voltage Reference voltage source Output current Synchronization Input current t 10 ms Window Monitoring Input voltage Enable Schmitt Trigger Input voltage Driver Output Collector voltage Storage temperature range Junction temperature Ambient temperature range 3 -Vo Tstg Tj Tamb VS to 2 -40 to +125 125 0 to 100 V C C C 6 5 -V1 VRef to 0 V -V1 VRef to 0 V 8 Pin 2 -IS -is -VS IO ISync. iSync. 10 60 32 3 5 20 mA mA V mA mA mA Symbol Value Unit
4
5. Thermal Resistance
Parameters DIP8 Junction ambient SO8 on PC board SO8 on ceramic Symbol RthJA RthJA RthJA Value 110 220 140 Unit K/W K/W K/W
9
4769C-INDCO-07/05
6. Electrical Characteristics
VS = -18V, Tamb = 25C, reference point pin 1, unless otherwise specified. Parameters Supply-voltage limitation Current consumption Supply-voltage Monitoring ON-threshold OFF-threshold Reference voltage Synchronization Input current Voltage limitation Remaining phase angle min threshold Zero identification ON Zero identification OFF 4 Vsync +Vsync -Vsync -Vsync +Vsync 6 -VI/VRef -VI/VRef 5 -VI/VRef -VI/VRef 5 VI/VRef VI II 3 I3 = 100 mA V3-2 I3 100 2 V mA 0.25 0.20 100 100 0.15 200 500 mV nA 0.33 0.62 0.3 0.6 0.27 0.58 OFF ON 1 f = --------------------------------1.6 x R t x C t 7-1 7-8 7 0.52 0.67 0.49 0.65 0.46 0.63 V4 limit V4 limit 6.5 to 7.8 V4 limit 6.5 to 7.8 V V V V I4 = 1 mA ON Off 4 VT IT VT IT 1.5 8.5 4 20 V A V A I8 = 0.1 mA I8 = 1.5 mA 8 4 isync Vsync VT VT 0.1 8.8 3.6 1.8 9.4 4 2 1.1 10 4.4 2.2 mA V V V Test Conditions IS = 800 A IS = 2 mA I3 = 0 2 -VS -VS -VRef -VRef 4.95 4.75 15 6.5 5.45 5.45 V V V V Pin 2 Symbol -VS -VS -IS Min. 21 21.3 Typ. Max. 23 24 750 Unit V V A
Operation Selection Zero voltage switch min operation DC mode Window Monitoring, Figure 3-7 on page 9 Threshold 1 Threshold 2 Enable Schmitt Trigger, Figure 3-6 on page 8 Threshold 1 Threshold 2 Oscillator Threshold 1 Threshold 2 Input current Output Stage Saturation voltage Output current
10
U2100B
4769C-INDCO-07/05
U2100B
7. Applications
Figure 7-1.
N 1 390 Triac R0 C0 1N4007 D1 -VS 2 330 nF 390 3 R3 220 k/0.5 W D3 1N 4148 D4 5.1 V 100 F R7 10 k C1 Tracking time 2.5 M R5
+
Lamp Time Control 18 Seconds to 23 Minutes for Two-wire Systems
8 330 nF 7
U2100B
6
C3 Timer start
R2 4 5 33 k R6 R4
-
S1
33 k C2 4.7 F
D2 22 V L
Figure 7-2.
Fan Tracking Time Control 18 Seconds to 23 Minutes
N M R2 5
R7
4 100 k
330 nF C0
390 R0
6 100 k C3 7 330 nF 8 R5 100 k C2 4.7 F R6 R4 2.5 M 33 k
D1
3
U2100B
2
S1 D1 C1
1
22 V 100 F REL 1000 L S1 open, motor starts
Tracking time adjustment
11
4769C-INDCO-07/05
8. Ordering Information
Extended Type Number U2100B-xY U2100B-xFPY U2100B-xFPG3Y Package DIP8 SO8 SO8 Remarks Tube Tube Taped and reeled
9. Package Information
P a c k a g e D IP 8
D im e n s io n s in m m
9 .8 9 .5 1 .6 4 1 .4 4 7 .7 7 7 .4 7
4 .8 m a x 6 .4 m a x 0 .5 m in 0 .5 8 0 .4 8 7 .6 2 8 5 2 .5 4 3 .3 0 .3 6 m a x 9 .8 8 .2
te c h n ic a l d ra w in g s a c c o rd in g to D IN s p e c ific a tio n s
1
4
12
U2100B
4769C-INDCO-07/05
U2100B
Package SO8
Dimensions in mm
5.00 4.85 1.4 0.4 1.27 3.81 8 5 0.25 0.10 0.2 3.8 6.15 5.85 5.2 4.8 3.7
technical drawings according to DIN specifications
1
4
10. Revision History
Please note that the following page numbers referred to in this section refer to the specific revision mentioned, not to this document. Revision No. 4769C-INDCO-07/05 4769B-INDCO-12/04 History * Put datasheet in a new template * Section 3.5 "Tracking Time Pin 7" on page 8 changed * Put datasheet in a new template * Table "Electrical Characteristics" on page 9 changed
13
4769C-INDCO-07/05
Atmel Corporation
2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 487-2600
Atmel Operations
Memory
2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314
RF/Automotive
Theresienstrasse 2 Postfach 3535 74025 Heilbronn, Germany Tel: (49) 71-31-67-0 Fax: (49) 71-31-67-2340 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759
Regional Headquarters
Europe
Atmel Sarl Route des Arsenaux 41 Case Postale 80 CH-1705 Fribourg Switzerland Tel: (41) 26-426-5555 Fax: (41) 26-426-5500
Microcontrollers
2325 Orchard Parkway San Jose, CA 95131, USA Tel: 1(408) 441-0311 Fax: 1(408) 436-4314 La Chantrerie BP 70602 44306 Nantes Cedex 3, France Tel: (33) 2-40-18-18-18 Fax: (33) 2-40-18-19-60
Biometrics/Imaging/Hi-Rel MPU/ High Speed Converters/RF Datacom
Avenue de Rochepleine BP 123 38521 Saint-Egreve Cedex, France Tel: (33) 4-76-58-30-00 Fax: (33) 4-76-58-34-80
Asia
Room 1219 Chinachem Golden Plaza 77 Mody Road Tsimshatsui East Kowloon Hong Kong Tel: (852) 2721-9778 Fax: (852) 2722-1369
ASIC/ASSP/Smart Cards
Zone Industrielle 13106 Rousset Cedex, France Tel: (33) 4-42-53-60-00 Fax: (33) 4-42-53-60-01 1150 East Cheyenne Mtn. Blvd. Colorado Springs, CO 80906, USA Tel: 1(719) 576-3300 Fax: 1(719) 540-1759 Scottish Enterprise Technology Park Maxwell Building East Kilbride G75 0QR, Scotland Tel: (44) 1355-803-000 Fax: (44) 1355-242-743
Japan
9F, Tonetsu Shinkawa Bldg. 1-24-8 Shinkawa Chuo-ku, Tokyo 104-0033 Japan Tel: (81) 3-3523-3551 Fax: (81) 3-3523-7581
Literature Requests
www.atmel.com/literature
Disclaimer: The information in this document is provided in connection with Atmel products. No license, express or implied, by estoppel or otherwise, to any intellectual property right is granted by this document or in connection with the sale of Atmel products. EXCEPT AS SET FORTH IN ATMEL'S TERMS AND CONDITIONS OF SALE LOCATED ON ATMEL'S WEB SITE, ATMEL ASSUMES NO LIABILITY WHATSOEVER AND DISCLAIMS ANY EXPRESS, IMPLIED OR STATUTORY WARRANTY RELATING TO ITS PRODUCTS INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, OR NON-INFRINGEMENT. IN NO EVENT SHALL ATMEL BE LIABLE FOR ANY DIRECT, INDIRECT, CONSEQUENTIAL, PUNITIVE, SPECIAL OR INCIDENTAL DAMAGES (INCLUDING, WITHOUT LIMITATION, DAMAGES FOR LOSS OF PROFITS, BUSINESS INTERRUPTION, OR LOSS OF INFORMATION) ARISING OUT OF THE USE OR INABILITY TO USE THIS DOCUMENT, EVEN IF ATMEL HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Atmel makes no representations or warranties with respect to the accuracy or completeness of the contents of this document and reserves the right to make changes to specifications and product descriptions at any time without notice. Atmel does not make any commitment to update the information contained herein. Unless specifically provided otherwise, Atmel products are not suitable for, and shall not be used in, automotive applications. Atmel's products are not intended, authorized, or warranted for use as components in applications intended to support or sustain life.
(c) Atmel Corporation 2005. All rights reserved. Atmel (R), logo and combinations thereof, Everywhere You Are (R) and others, are registered trademarks or trademarks of Atmel Corporation or its subsidiaries. Other terms and product names may be trademarks of others.
Printed on recycled paper.
4769C-INDCO-07/05